clean agent electrical fire suppression system manufacturer, kitchen fire suppression system supplier, vehicle fire suppression system services, co2 system fire protection, fire fighting system, fire protection system.

Plot No. 71, Sewak Park, Dwarka More Metro Station, Near Pillar No. 776, Uttam Nagar

Call@ 9971365130, 9990360705

Call@ 9971365130, 9990360705

  • Home
  • Products
  • FIRE SUPPRESSION AGENTS
  • Fire extinguishing system
  • Shop
  • Checkout
  • Return and Refund Policy
  • More
    • Home
    • Products
    • FIRE SUPPRESSION AGENTS
    • Fire extinguishing system
    • Shop
    • Checkout
    • Return and Refund Policy
  • Sign In
  • Create Account

  • Orders
  • My Account
  • Signed in as:

  • filler@godaddy.com


  • Orders
  • My Account
  • Sign out

Signed in as:

filler@godaddy.com

  • Home
  • Products
  • FIRE SUPPRESSION AGENTS
  • Fire extinguishing system
  • Shop
  • Checkout
  • Return and Refund Policy

Account


  • Orders
  • My Account
  • Sign out


  • Sign In
  • Orders
  • My Account
FIRE ENGINEERING TECHNOLOGY

FIRE ENGINEERING TECHNOLOGY

FIRE ENGINEERING TECHNOLOGYFIRE ENGINEERING TECHNOLOGY

Your safety is our priority with top-quality equipment.

Get in Touch
Learn More

About FIRE ENGINEERING TECHNOLOGY

Our Expertise

At FIRE ENGINEERING TECHNOLOGY, we have over 15 years of experience in the fire protection equipment industry. Our team of experts is highly trained and knowledgeable in all aspects of fire safety.

Our Commitment to Quality

We are committed to providing our customers with the highest quality fire protection equipment and services. All our products are tested and certified to meet industry standards.

Our Customer Service

At FIRE ENGINEERING TECHNOLOGY, we pride ourselves on our exceptional customer service. Our team is always available to answer any questions and provide support to our valued customers.

Fire Protection Equipment Supplier

Electrical Fire suppression system

flexible polymer tube based gas suppression system

 A tube-based electrical fire suppression system is a type of automatic fire suppression system designed specifically to detect and extinguish fires in electrical enclosures or other small, enclosed areas (like control panels, server cabinets, or switchgear). 


 How It Works:

The system typically uses a flexible detection tube that is routed inside or around the electrical panel or cabinet. Here's how it operates:

  1. Fire Detection: 
    • The tube is pressurized and made of a material (usually a polymer) that ruptures when exposed to high heat—typically in the range of 100°C to 180°C.
       
    • When a fire starts, the rising heat causes the tube to burst at the hottest point, effectively acting as both a sensor and discharge nozzle.
       

  1. Fire Suppression: Once the tube bursts, it releases a clean agent (such as FM-200, Novec 1230, CO₂, or dry chemical powder) directly at the source of the fire.
     
    • These agents are non-conductive, leave no residue, and are safe for use around electronics.
       

  1. Immediate Response: 
    • The localized nature of the system means it responds quickly, minimizing damage and downtime.

 

Advantages:

  • No electricity required to operate
     
  • Quick detection and suppression at the fire’s origin
     
  • Low maintenance
     
  • Compact and easy to retrofit
     
  • Minimizes collateral damage

Kitchen fire suppression system

Detection tube based wet chemical based kitchen fire suppression system

 A tube-based kitchen fire suppression system is an automatic, self-contained fire protection system designed to suppress fires that typically occur in commercial or residential kitchen hoods, ducts, and cooking appliances. 

It uses a flexible detection and discharge tube that detects heat and releases a special wet chemical agent to extinguish fires quickly and safely. 


 

How It Works (Kitchen Application):

  1. Detection Tube Installation: 
    • A polymer detection tube is routed inside the kitchen hood or over cooking appliances.
       
    • The tube is pressurized and constantly monitors for heat.
       

  1. Fire Detection: 
    • If a fire starts (e.g., grease fire), the heat causes the tube to rupture at the hottest point (typically 170°C to 180°C).
       
    • This acts as a trigger, either releasing the suppression agent directly from the burst point or activating a separate cylinder via pressure drop.
       

  1. Agent Discharge: 
    • The system releases a wet chemical agent (e.g., potassium acetate-based) that:
       
      • Rapidly cools the flames.
         
      • Forms a soapy layer (saponification) over hot oil or grease to prevent reignition.
         

  1. Optional Gas Shutoff: 
    • Many systems include an optional automatic gas shutoff valve to cut off the fuel source when the system activates.

    Feature Benefit     No electricity required Works during power failure   Automatic detection & suppression Quick response, 24/7 protection   Compact & clean Ideal for kitchens with limited space   Safe for grease fires Specifically designed for oil/grease-based fires   Easy to install/retrofit Minimal disruption to kitchen operations    .

CNC Machine fire suppression system

CNC machine fire suppression system

 

A tube-based fire suppression system for CNC machines is a specialized, compact solution designed to automatically detect and suppress fires inside enclosed machining centers, where the risk of fire is high due to:

  • Hot chips/sparks 
  • Flammable coolants/lubricants 
  • High-speed spindles and motors

 

How It Works (Tube-Based CNC Fire Suppression):

  1. Detection Tube Installation: 
    • A flexible polymer detection tube is installed inside the CNC enclosure, above high-risk areas (e.g., spindle, coolant lines, electrical compartments).
       
    • The tube is pressurized and acts as both a sensor and discharge line.
       

  1. Fire Detection: 
    • When a fire occurs, rising heat (typically 170°C–180°C) causes the tube to rupture at the hottest point.
       
    • This triggers immediate agent discharge at the fire’s origin.
       

  1. Agent Discharge: 
    • A clean agent (like Novec 1230 or FM-200) is released either:
       
      • Directly from the rupture point, or
         
      • Through nozzles, if the system uses the tube only as a detection mechanism (indirect system).
         
    • The agent suppresses the fire without damaging sensitive electronics or leaving residue.

    Feature Benefit     Fast, localized response Prevents spread of fire inside enclosed space   No power required Operates even during machine shutdown   Clean agent No residue or corrosion; safe for electronics & optics   Compact & flexible Easy to retrofit inside tight enclosures   Low maintenance Typically requires only periodic inspection    

Fume Hood fire suppression system

Fume hood fire suppression system

 A tube-based fire suppression system for a fume hood is an automatic, self-activating system designed to detect and suppress fires directly inside the fume hood workspace. These systems are ideal for laboratories, pharmaceutical environments, and chemical processing areas, where fires may start due to flammable substances or reactions during experiments. 


 

How It Works (Tube-Based Fume Hood Fire Suppression):

  1. Detection Tube Placement: 
    • A flexible, heat-sensitive polymer detection tube is routed inside the fume hood sash area, directly above or around the work zone.
       
    • The tube is pressurized and serves as both a detection sensor and discharge mechanism.
       

  1. Fire Detection: 
    • If a fire breaks out (e.g. due to volatile chemicals or a burner), the heat causes the tube to rupture at the hottest point.
       
    • This triggers immediate release of the suppression agent, either:
       
      • Directly through the burst point (direct system), or
         
      • Through fixed nozzles, activated via pressure loss (indirect system).
         

  1. Suppression Agent Discharge: 
    • A clean or chemical agent is released to quickly suppress the fire and prevent it from spreading or reigniting.
       
    • The system is typically non-electric, allowing for fail-safe operation during power outages.

    Feature Benefit     Automatic, fast response Stops fires before they can spread   No external power required Works 24/7 even during electrical failures   Clean, residue-free agents Safe for lab instruments, samples, electronics   Compact & unobtrusive Does not interfere with normal lab work   Easy retrofit/install No major ductwork or infrastructure changes needed.


 

Typical Use Cases:

  • Chemical and analytical laboratories
     
  • University research labs
     
  • Pharmaceutical R&D hoods
     
  • Semiconductor process hoods
     
  • Forensic labs

Smart Rack fire suppression system

 A tube-based fire suppression system for smart racks (also known as IT racks, network cabinets, or server enclosures) provides localized, automatic fire protection directly inside sensitive electronic enclosures — without requiring electricity or complex infrastructure. This is especially critical in data centers, edge computing, telecom installations, and IoT hubs, where uptime and equipment protection are essential. 


 How Tube-Based Smart Rack Fire Suppression Works:

  1. Detection Tube Installation: 
    • A flexible, pressurized polymer tube is routed inside the rack enclosure, above and around potential ignition sources (e.g., power supplies, switchgear, routers, servers).
       
    • The tube continuously monitors for abnormal heat. 

  1. Fire Detection: 
    • When heat from an electrical fault or overheating component reaches the tube’s activation temperature (typically 170–180°C), the tube ruptures at the hottest point.
       

  1. Agent Discharge: 
    • The system instantly releases a clean suppression agent:
       
      • Direct System: Agent is discharged directly from the burst tube point.
         
      • Indirect System: The rupture triggers a valve to release the agent through dedicated nozzles for more controlled coverage.

    Feature Benefit     Localized protection Suppresses fires inside the rack before they spread   No power required Functions during power outages or shutdowns   Non-conductive, clean agents Safe for electronics, leaves no residue or damage   Compact and space-efficient Perfect for enclosed spaces like 19” racks   24/7 autonomous monitoring No human interaction needed for activation .


 

🔌 Optional Features for Smart Rack Systems:

  • Dry contact relays for alerting servers or shutting down power
     
  • Integration with building fire alarm systems (FACP)
     
  • BMS/SCADA/IoT integration for remote monitoring
     
  • LED indicators, audible alarms, and event logs
     

📘 Ideal Use Cases:

  • Data centers (core or edge)
     
  • Remote telecom nodes and BTS cabinets
     
  • Factory floor IIoT smart cabinets
     
  • Industrial control enclosures
     
  • Financial or medical IT closets

vehicle fire suppression system

AFDSS or Vehicle fire suppression system

 

A tube-based vehicle fire suppression system is a self-contained, automatic fire protection system designed to detect and suppress fires in vehicles such as:

  • Buses and coaches
     
  • Mining trucks and construction equipment
     
  • Military vehicles
     
  • Agricultural machines (e.g., combines, tractors)
     
  • Commercial trucks and vans
     

This system offers early detection and immediate suppression at the source — often in the engine bay, battery compartment, or hydraulic systems, where most vehicle fires start.

 

How a Tube-Based Vehicle Fire Suppression System Works:

  1. Detection Tube Installation: 
    • A flexible, heat-sensitive polymer tube is routed throughout high-risk areas of the vehicle (engine, battery compartment, hydraulic lines).
       
    • The tube is pressurized with nitrogen and monitors 24/7 for rising temperatures.
       

  1. Fire Detection: 
    • If a fire breaks out, the tube bursts at the hottest point (typically around 170–180°C / 340–356°F).
       

  1. Suppression Agent Discharge: 
    • The system instantly discharges the agent:
       
      • Direct System: Agent is released directly through the burst hole in the tube.
         
      • Indirect System: Pressure drop opens a valve to discharge agent via pre-installed nozzles.

    Agent Type Features Best Use In Vehicles     Dry Powder (ABC) Inexpensive, good for oils and fuels Common in mining, buses, off-road vehicles   AFFF Foam Cools and suppresses flammable liquid fires Engine compartments, fuel tanks   Novec 1230 Clean, no residue, safe for electronics EVs, hybrid systems, battery enclosures   CO₂ Effective in closed spaces, leaves no residue Not ideal for passenger compartments .


 Key Benefits for Vehicle Use: 

    Feature Benefit     No power needed System operates even during full electrical failure   Automatic and instant action No driver input required   Prevents full-vehicle loss Contains fire before it spreads   Compact & rugged Designed for vibration, heat, and dust   Low maintenance Long service life with periodic inspections .


 

🚛 Common Installation Zones:

  • Engine compartment
     
  • Battery bank (especially for EVs)
     
  • Hydraulic pump/motor areas
     
  • Fuel tank or filler areas
     
  • Wheel well or braking zones (for buses, trailers)
     

🔒 Optional Features:

  • Manual activation button
     
  • Alarm or alert integration in the cab
     
  • Engine shut-off trigger
     
  • Telematics/BMS integration
     

⚙️ Ideal Vehicle Types by Sector:

    Sector Vehicles Protected     Public Transit Buses, minibuses, light rail   Mining & Construction Excavators, dump trucks, dozers   Agriculture Combines, harvesters, tractors   Military Armored vehicles, troop carriers   Commercial Fleet Trucks, trailers, vans    


fire suppression system MANUFACTURER AND SUPPLIER

Contact Us

Drop us a line!

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Better yet, see us in person!

clean agent fire suppression system, fire fighting system, co2 system fire protection system solution by FIRE ENGINEERING TECHNOLOGY.


We love our customers, so feel free to visit during normal business hours.

Call@ 9971365130, 9990360705

Info@fireengineeringtechnology.com

Message us on WhatsApp

FIRE ENGINEERING TECHNOLOGY

Plot No. 71, Sewak Park, Dwarka More Metro Station, Near Pillar No. 776, Uttam Nagar

9015080056, 9971365130, 8860101989, 9971365130 INFO@FIREENGINEERINGTECHNOLOGY.COM, ANIL@FIREENGINEERINGTECHNOLOGY.COM, RAHUL@FIREENGINEERINGTECHNOLOGY.COM & FireET2014@GMAIL.COM

Hours

Mon

09:00 am – 06:00 pm

Tue

09:00 am – 06:00 pm

Wed

09:00 am – 06:00 pm

Thu

09:00 am – 06:00 pm

Fri

09:00 am – 06:00 pm

Sat

09:00 am – 06:00 pm

Sun

Closed

24x7 online support available


Copyright © 2025 FIRE ENGINEERING TECHNOLOGY - All Rights Reserved.

Powered by

  • Products
  • Shop
  • Checkout
  • Terms and Conditions
  • Privacy Policy
  • Satisfied Customers

This website uses cookies.

We use cookies to analyze website traffic and optimize your website experience. By accepting our use of cookies, your data will be aggregated with all other user data.

Accept

Call : 9971365130, 9990360705

FIRE SUPPRESSION SYSTEM